A drive is rarely the problem; the panel around it usually is. Most of the pump stations we automate run Altivar drives, and this page covers the family as we actually deploy it: sized, protected, bypassed where the duty demands it, and built into panels tested before they reach site.
The platform
The Altivar ATV320 is Schneider Electric's machine-duty variable speed drive, and it is the drive we install most: duty and standby pairs on irrigation and stormwater pumps across Abu Dhabi's parks and municipal stations, typically in the low tens of kilowatts, mounted in motor control centres we build in our own Mussafah workshop. Around it sit the family members the archive of our delivered projects also names, the ATV310 and ATV212, and larger drives where a station's pumps demand them.
What decides whether a drive installation is any good is mostly not the drive. It is the sizing against the real duty, the incomer protection and earth-leakage arrangement, how the drive's own protection talks to the pump manufacturer's modules, the changeover logic between duty and standby, and whether the panel keeps the electronics within temperature in a UAE plant room. That is panel engineering, and it is the part we own end to end.
The drives sit inside a documented delivery record: twelve duty-and-standby pump sets across four park programmes, the Shakhbout City pump rooms on ATV320 pairs, the Al Ain parks programme, and stormwater and irrigation stations where drive, PLC, RTU and instrumentation arrive as one tested panel.
The work
MCCs with the drive, incomer protection, earth leakage, metering, changeover and control logic assembled and factory tested in Mussafah, so site work is installation and commissioning rather than fabrication.
Motor rating, cable lengths, switching frequency and the actual hydraulic duty, not catalogue optimism. On duty and standby pairs, sized so either drive carries the station alone.
The drive's protection and the pump manufacturer's own modules each see part of the truth. We wire and configure them to act as one scheme, so the station reports why it stopped rather than just that it stopped.
Swapping obsolete or failed drives inside existing panels, including reworking control wiring and parameters so the new drive behaves like the station expects, part of our wider PLC and drive replacement work.
Where ratings climb into the hundreds of kilowatts, harmonic behaviour becomes a design input; our VFD panel guide covers when a low harmonic solution is genuinely needed and what it changes in the panel.
The drive is commissioned with the PLC, RTU and instrumentation as one system: ramps, interlocks, changeover and the telemetry the municipal SCADA expects, proven end to end before handover.
Before you buy
Track record
Drive panels inside documented deliveries across Abu Dhabi and Al Ain.
Department of Municipalities & Transport, Abu Dhabi (DMT)
Department of Municipalities and Transport, Abu Dhabi (DMT)
Department of Municipalities and Transport, Abu Dhabi (DMT)
Al Hamra Zone 2 development, to Etihad Water and Electricity specifications
Common questions
It is a machine-duty variable speed drive, and in our work it runs pumps: duty and standby irrigation and stormwater pump pairs in the low tens of kilowatts across Abu Dhabi's parks and municipal stations. It sits in a motor control centre with the protection, changeover and control logic around it, which is where most of the engineering actually lives.
Yes, and it is routine work for us: physical fit, control wiring rework and parameter configuration so the new drive behaves the way the station and its SCADA expect. Where the old drive is obsolete, we advise on the closest current member of the family and what changes around it.
The whole panel is our normal scope: drive, incomer and earth leakage protection, metering, changeover, PLC and instrumentation interfaces, assembled and factory tested in our Mussafah workshop. A drive dropped into a poorly engineered panel inherits every one of that panel's problems.
Mostly at larger ratings or where the supply or specification demands it; at typical park pump ratings it is rarely justified. Our VFD control panel guide covers the decision in detail, including a delivered 315 and 250 kW low harmonic case.
The delivered record names the Altivar ATV320 most often, with the ATV310 and ATV212 also appearing across the archive, always inside panels we built and commissioned. We keep this page to what the project record shows rather than the full catalogue.